A fire resistant roof panel should be selected against the fire requirement for the complete roof, not its core name alone. Buyers need to distinguish reaction to fire, timed fire resistance and external roof exposure, then check that the supporting documents cover the panel configuration, joints and installation proposed for their building.
This guide uses Fuqiang’s published roof-panel specifications checked on September 22, 2026. It explains what to request during procurement; it does not assign a fire-resistance duration to an untested roof assembly. The project designer and relevant approving authority should confirm the required evidence before an order is released.
The phrase “fire resistant” can hide several different questions. A warehouse specification may concern the way a product contributes to a fire, the performance of a separating roof assembly during a fire, or exposure to fire from outside. A brochure statement cannot answer all of these questions at once.
| Requirement | What the evidence addresses | Buyer check |
|---|---|---|
| Reaction to fire | How a material or product behaves when exposed to fire under a specified classification system. | Ask for the classification and the tested product construction. Do not convert a class into a duration in minutes. |
| Fire resistance | How an assembly maintains the required functions during a defined fire test. | Confirm the applicable criteria, duration, exposure direction, support arrangement and permitted variations. |
| External roof fire performance | Roof behaviour under the external exposure conditions of the applicable test. | Check the complete build-up, roof covering, slope and substrate covered by the evidence. |
| Insurance or project approval | Additional requirements imposed by the insurer, client or local approval process. | Obtain the exact acceptance requirements before comparing supplier claims. |
ASTM E84, for example, concerns surface burning characteristics, including flame spread and smoke development. It does not establish a timed roof-assembly fire-resistance rating. EN 14509 concerns factory-made self-supporting double-skin metal-faced insulating panels; a reference to that standard is not, on its own, evidence that every proposed installation satisfies the project’s fire requirements.
Mineral wool and polyurethane are different insulation materials, but the procurement decision also involves facings, bonding, edge details and joints. Compared with a simple metal roof sheet, an insulated sandwich panel combines the weather-facing skin and insulation in one factory-made component. That can simplify material coordination while making the exact panel construction important to the evidence review.
| Panel family | Reason to consider it | Limit or verification point |
|---|---|---|
| Rock wool sandwich panel | A mineral-fibre core can be relevant where fire-related requirements influence material selection. | The core description does not establish the performance of facings, adhesive, joints or the complete roof. |
| PU sandwich panel | Fuqiang publishes a lower thermal-conductivity value for its PU roof product than for its PU edge-sealed rock wool roof product. | Thermal performance cannot substitute for fire evidence. Confirm the specific foam formulation and panel construction covered by the report. |
| PU edge-sealed rock wool panel | Combines a rock wool core with a PU edge treatment intended to protect the core edges and support joint coordination. | It contains more than mineral wool. Check that the edge treatment and joint match the tested or assessed configuration. |

The figures below come from the corresponding Fuqiang product pages. They are published product information, not independent verification of a fire test. Both pages reference GB 8624 Grade B1; neither reference should be relabelled as a specific number of minutes of roof fire resistance or transferred to another country’s classification system.
| Published specification | PU edge-sealed rock wool corrugated roof panel | Hidden-fastener PU three-wave roof panel |
|---|---|---|
| Effective coverage | 1,000 mm | 1,000 mm |
| Core thickness options | 50 / 60 / 75 / 80 / 100 / 150mm | 50 / 60 / 75 / 80 / 100 / 150mm |
| Steel facing thickness | 0.4–0.8 mm | 0.4–0.8 mm |
| Published thermal conductivity | 0.035–0.041 W/(m·K) | ≤0.023 W/(m·K) |
| Fire statement on product page | GB 8624 Grade B1; request the applicable report. | GB 8624 Grade B1; request the applicable report. |
Review the PU edge-sealed rock wool roof-panel specifications and the hidden-fastener PU roof-panel specifications with the supplier. Thermal conductivity is not the same as the installed roof U-value; the project calculation must consider the actual thickness and construction details.

A project may select a mineral-wool panel and later change the joint sealant, fastener layout or rooflight system to simplify installation. The core has not changed, but the roof assembly has. The original evidence may no longer cover the proposed build-up.
Keep a deviation register alongside the roof drawings. For each change, identify the affected report or detail and obtain the designer’s acceptance before installation. Where the supporting documentation does not cover the change, request an appropriate assessment or tested alternative. Increasing panel thickness alone does not resolve an unsupported joint or penetration.
Fire selection also needs to coexist with structural and weathering design. Ask for the applicable load-span information, wind-uplift fixing requirements and drainage details. A fire-related claim does not establish allowable purlin spacing, resistance to leakage or safe access loads.
Send the roof plan and sections, project location, building use, required fire documentation and target thermal performance. Include the intended panel dimensions, quantities, facing gauge, coating, support layout and roof openings. For renovations, describe the existing substrate and any materials that will remain in place.
Fuqiang supplies these roof panels on a quotation basis. There is no verified universal price per square metre for the configurations in this guide. Request separate confirmation of panels, flashings, fasteners, packaging and shipping so competing offers cover the same scope.
Use the roofing application information to prepare a drawing-based enquiry. Ask the supplier to return a document list and a marked-up configuration before accepting the commercial quotation; missing test coverage is easier to resolve before manufacturing.
The Shandong Fuqiang Technical & Application Team supports product configuration and application enquiries for insulated panels and roof systems. This guide draws on the company’s published product information and the standards references described above. Project-specific compliance requires the applicable reports and review by the responsible project professionals.
No. The core alone does not establish the rating of the complete roof assembly. Check the applicable test or assessment and its scope, including panel construction, supports, joints and installation details.
No. A burning-behaviour classification must not be converted into a duration in minutes. Request the exact report and ask the project designer whether it addresses the required roof performance.
Do not assume it can. Roof and wall applications may have different support conditions, orientation, exposure and acceptance criteria. The evidence must cover the proposed roof configuration.
Check the full panel construction, including the PU edge treatment, facings, joints and fasteners. Match the supplied configuration to the supporting report rather than relying only on the mineral-wool core description.